Conventional Fire Alarm Control Panel,alarm control panel,fire alarm panel

Conventional Fire Alarm Control Panel,alarm control panel,fire alarm panel
Product Detailed
Conventional Fire Alarm Control Panel, is also called alarm control panel and fire alarm panel.

Key words: Fire alarm Control Panel,conventional fire alarm control panel,  fire alarm panel, fire alarm, FACP, fire alarm system, fire-fighting

Feature 

1) 4/8/16 Style B (Class B) Initiating Device Circuits (IDCs).

    - All zones accept two-wire smoke detectors and any normally-open contact devices.

    - Zones 1 4/8/16 configured as general alarm zones.

2) All circuits are power-limited and supervised, meeting the latest ULC requirements using fuseless technology.

3) Two built-in, Style Y (Class B) Notification Appliance (Signal) Circuits (NACs).

4) NACs may be programmed:

    - Silenceable

    - Non-Silenceable

    - Auto-Silence (program 5 to 20 minutes)

5) 1.25 amps of NAC power

6) 3.0 amps of total system power

7) Alarm, Trouble and Supervisory, Form-C relays standard.

8) 24-volt operation

9) Resettable four-wire smoke detector power @ 500 mA

10)  Non-resettable power @ 500 mA

11) Integral battery charger capable of charging up to 18 AH batteries (batteries over 4 AH require use of the external battery backbox, or ULC listed equivalent).

12) One-man walk-test programmable for silent or audible test

13) Disable/Enable control per IDC

14) Reverse polarity protection

15) Control buttons: 

      - Mode

      - Test

      - ACK (Acknowledge) Alarm Silence

      - Reset

16) Meet UL864, EN-54 standard.

17) LED indicators:

      - AC Power (green & yellow LED)

      - Fire Alarm (red LED)

      - Trouble (yellow LED)

      - Supervisory (yellow LED)

      - Signal Silence (yellow LED)

      - Battery Power (green & yellow LED)

      - Zone Disable (yellow LED)

      - NAC Fault (yellow LED)

      - NAC Disable (yellow LED)

      - 4/8/16 Zone Alarm (one for each zone) (red LED)

      - 4/8/16 Zone Trouble (one for each zone) (yellow LED)

      - Earth Fault (on circuit board)

      - Battery Fault (on circuit board)

      - Charger Fault (on circuit board)

  

Specifications

  

AC Power: AC220V±10% 50Hz, 2.0 amps, minimum 14 AWG wire (2.0 mm²) with 600-volt insulation.

Battery: Sealed lead-acid batteries only, Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge, Maximum battery charger capacity: 18AH battery

NOTE: two 4AH batteries can be housed in the cabinet. Larger batteries require a separate battery box.

Total 24 V system power: 3.0 amps         

Notification appliance (signal) power: 2.5 amps

Maximum current per NAC: 1.25 amps (expandable to 2.5 amps)

Auxiliary Outputs:   - Resettable four-wire smoke detector power @ 500 mA

                                  - Non-resettable power @ 500 mA

                                  - Integral Form-C Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive)

 

NOTE: Total current for auxiliary power outputs and two NACs must not exceed 3.0 amps.

Dimensions: 320×260×80mm (length × width × depth)

Using Environment: Temperature: 10°C~+50°C.

Related Humidity: ≤95% (40±2°C)

Orena Sales and Service

Shenzhen Orena Photonic Technology Co., Ltd

Orena Bldg, Zhong'an Industrial Park, Longjing Road, Nanshan District, Shenzhen, 518055, China

Tel: 86.755.2678.7499  Fax: 86.755.2678.7499

Conventional Fire Alarm Control Panel,alarm control panel,fire alarm panel



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.